Feature:
1. SAFE AND FLAME RETARDANT MATERIAL: This automatic transfer switch is made of excellent flame retardant PC materials, possess good insulation, high temperature resistant, aging resistant, safe and , use silver contacts can greatly improve the conductivity and service life of the product
2. 2 MODES: Power transfer switch support automatic or manual , has compact structure, , convenient installation and maintenance, long service life
3. 35MM STANDARD RAIL MOUNTING: power automatic switch is a miniature household power switch, which is mainly used to test whether the main power supply or backup power supply is normal to the continuity, reliability and safety of the power supply, designed for rail mounting, specially for PZ30 distribution box
4. MILLISECONDS SWITCHING: Automatic transfer switch is very useful, when the normal power supply is abnormal, the backup power supply works immediately, and the power supply is switched in milliseconds without interruption
. WIDE APPLICATION: Power transfer switch switch to the backup power supply when there is a power failure, and switch to the main power supply when power recovery, suitable for 50 or 60Hz AC rated 230V emergency power supply system, widely used in various places where continuous power failure is not allowed, like factories, shopping malls, nurseries, etc.
Specification:
Item Type: Power Automatic Transfer Switch
Model: NLQ5 100 2P
Material: PC flame retardant, silver
Insulation Voltage Ui: AC690V 50Hz
Rated Voltage Ue: AC400V 50Hz
Frequency: 50/60Hz
Level: PC level
Specifications: 2P
Rated Control Voltage US: 220VAC 85%Us-110%Us
Life: Electrical: 2000 Times; Mechanical: 5000 Times
Rated Short Circuit Current: 50kA
: RT16-00-63A
Rated Impulse Withstand Voltage: 8kV
Auxiliary Circuit: Two relays, Each Relay Has Two Sets of Contacts Capacity: AC220V50HZ le=5y
Touch Time: <50ms
Transition Time: <50ms
Return Time: <50ms
Off Time: <50ms
Package List:
1 x Power Automatic Transfer Switch
2 x Protective Cover
1 x Accessory
1 x User Manual
Note:
1. The maximum ambient temperature should not exceed 40??, the minimum should not be lower than ???, and the average temperature within 24 hours should not be higher than 35??.
2. The altitude of the installation site should not be higher than 2000meter.
3. When the maximum temperature reaches 40??, the relative humidity of the installation site should not exceed 50%; when the temperature is the lowest temperature of ???, the relative humidity is higher, for example, if the temperature is 25??, the relative humidity is 90%. Special measures should be taken to deal with occasional condensation on product surfaces due to temperature changes.